HOT WATER BOILERS

LXW Series Models
Including multiple water tubes, Miura’s natural gas/propane hot water boiler is a low water content, water tube design, which provides full output within 5 minutes. Miura's Low NOx Hot-Water Boiler utilizes a flat shaped burner and rectangular shaped boiler vessel uniquely designed for the LXW.
  • Typically only one-third the footprint of conventional firetube boilers
  • Low NOx gas burner with “Quenched flame”
  • Up to 175HP per boiler


EXW Series Models
Miura's Gas/Oil hot-water boiler is a low water content, water tube design, which provides full output within 5 minutes.
  • Gas/Oil dual fuel burner
  • Up to 300 BHP per boiler
LXW Series Boiler

LXW Series Hot-Water Boiler
50 BHP
LXW-100 G
LXW Series Hot-Water Boiler
100 BHP
LXW-150 G
LXW Series Hot-Water Boiler
150 BHP
LXW-175 G
LXW Series Hot-Water Boiler
175 BHP
EXW Boilers

EXW-100 GO
EXW Series Hot-Water Boiler
100 BHP
EXW-200 GO
EXW Series Hot-Water Boiler
200 BHP
EXW-300 GO
EXW Series Hot-Water Boiler
300 BHP
  LXW-50 LXW-100 LXW-150 LXW-175
Utilization Horsepower 50 BHP 100 BHP 150 BHP 175 BHP
Maximum Pressure 160 PSIG
Max. Water Temperature 250°F
Heat Output 1,674,000 BTU/HR 3,348,000 BTU/HR 5,022,000 BTU/HR 5,859,000 BTU/HR
Efficiency [1] 82%
Full Water Content 44 GAL 64 GAL 90 GAL 90 GAL
Heating Surface Area 177 FT² 247 FT² 404 FT² 404 FT²
Operational Weight 3,200 LBS 4,650 LBS 5,800 LBS 5,800 LBS
Shipping Weight 3,000 LBS 4,100 LBS 5,000 LBS 5,000 LBS
Width 33 in. 34 in. 44 in. 44 in.
Length 83 in. 97 in. 145 in. 150 in.
Height 106 in. 109 in. 111 in. 114 in.
Combustion System Proprietary Forced Draft, Step Fired Modulation Hi-Low-Off
Ignition System Electric Spark Ignited, Interrupted Gas Pilot
Power Supply 230, 460, 575V, 3 phase, 60Hz
Max. Electrical Consumption 3.7 KVA 9.5 KVA 14.1 KVA 14.1 KVA
Fuel Type [2] Natural Gas or Propane (3-5 PSIG)
Gas Consumption [3] 2,030 SCFH 4,070 SCFH 6,100 SCFH 7,120 SCFH
Gas Supply Pressure 3-5 PSIG (Natural Gas or Propane)
Main Water Outlet Valve 3 in. 4 in. 6 in. 6 in.
Safety Valve Outlet One 1 in. One 1 in. One 1 1/2 in. One 1 1/2 in.
Main Water Inlet 3 in. 4 in. 6 in. 6 in.
Fuel Gas Inlet 1 1/2 in. 2 in. 2 in. 2 in.
Manual Blowdown One 1 1/2 in. One 1 1/2 in. One 1 1/2 in. One 1 1/2 in.
Chimney Diameter (ID) 12 in. 14 in. 14 in. 20 in.
Flame Detector Ultraviolet Flame Eye Sensor
Temperature Control Adjustable Temperature Controllers
Overheat Protection Low Water Cut Off, Thermocouple & Flow Switch
Notes
  1. Thermal efficiencies are based on high heating values of fuels at 140°F supply temperature water.
  2. UL and CGA/CSA approved for Natural Gas and Propane.
  3. Gas consumption based on natural gas with high heating 1004 BTU/SCF.

All Miura hot water boilers are fully packaged and test fired at factory. Built to meet or exceed UL and ASME standards in U.S.A.; CGA/CSA & B-51 standards in Canada. 49 BHP and 260 BHP units available on request.
  EXW-100 EXW-200 EXW-300
Utilization Horsepower 100 BHP 200 BHP 300 BHP
Maximum Pressure 160 PSIG
Max Water Temp 250°F
Heat Output 3,348,000 BTU/HR 6,695,000 BTU/HR 10,050,000 BTU/HR
Efficiency [1] 80% (82% Oil)
Full Water Content 85.5 GAL 140 GAL 148 GAL
Heating Surface Area 193 FT² 323 FT² 390 FT²
Operational Weight 5,400 LBS 9,600 LBS 14,200 LBS
Shipping Weight 4,700 LBS 8,400 LBS 12,900 LBS
Width 82 in. 89 in. 90 in.
Length 93 in. 103 in. 103 in.
Height 99 in. 120 in. 138 in.
Combustion System Proprietary Forced Draft
Ignition System Electric Spark Ignited, Interrupted Gas Pilot
Power Supply 230, 460, 575V, 3 phase, 60Hz
Max. Electrical Consumption 14 KVA 25 KVA 34 KVA
Fuel Type [2] Natural Gas, Propane or No. 2 Oil (3-5 PSIG)
Gas Consumption [3] 4,185 SCFH 8,368 SCFH 12,562 SCFH
No. 2 Oil 29.2 GAL/HR 58.3 GAL/HR 87.5 GAL/HR
Gas Supply Pressure 3-5 PSIG (Natural Gas or Propane)
Main Water Outlet 4 in. 6 in. 8 in.
Safety Valve Outlet 2 in. 2 in. 2 1/2 in.
Main Water Inlet 4 in. 6 in. 8 in.
Fuel Gas Inlet 2 in. 2 in. 2 1/2 in.
Fuel Oil Inlet 3/4 in. 3/4 in. 3/4 in.
Manual Blowdown 1 in. 1 in. 1 in.
Chimney Diameter (ID) 14 in. 20 in. 26 in.
Flame Detector Ultraviolet Flame Eye Sensor
Overheat Protection Low Water Cut Off & Flow Switch
Temperature Control Adjustable Temperature Controllers
Notes
  1. Thermal efficiencies are based on high heating values of fuels at 68°F (20°C) feed water.
  2. UL and c-UL approved for natural gas or propane.
  3. Gas consumption based on natural gas with high heating 1004 BTU/SCF.

All Miura hot water boilers are fully packaged and test fired at factory. Built to meet or exceed UL and ASME standards in U.S.A.; CGA/CSA and B-51 standards in Canada. 49 BHP and 260 BHP units available on request.